8. If using a Christie extractor, connect the line cord to the LPS connector labeled Extractor
ONLY.
9. Verify the LPS to projector connections by making sure that all cables connected to the LPS are
connected to the same projector.
Danger! Failure to comply with the following results in death or serious injury.
In a multi-projector installation there is a risk of a Fire Hazard if the high current DC cables
and interlock/control cables are incorrectly cross-connected between the projector heads
and lamp power supplies (LPSs). Make sure the high current DC Llds and interlock/control
cables are correctly connected between the LPS and its corresponding projector. Failure to
comply may result in a Fire Hazard.
10. Set the three LPS breakers to their on positions.
11. Set the projector breaker, located on the baseplate below the projector AC receptacle, to the on
position.

Configuring ballast settings for 200 VAC operation

1. Unplug the LPS from power.
2. Remove the front panel using a Phillips screwdriver.
3. Insert the convenience outlet harness (black) wire into the first position on the terminal block.