Power Requirements - Christie Mirage 4K35 User Manual

Hide thumbs Also See for Mirage 4K35:
Table of Contents

Advertisement

7kW Lamp Power Supply
Nominal voltage range
Operating voltage range
Number of phases
Line frequency
Inrush current
Current per phase
Power Consumption
Current rating of 3phase AC input
Lamp power supply output to projection head
Operating voltage range
Start-up voltage (open current)
Operating current range
Ripple
Connector type
Lamp power supply power receptacle output
Operating voltage range
Operating current range—projection head
Operating current range—heat extractor
Current rating of input

Power requirements

Projection Head
AC Input
Rated input voltage
Rated line frequency
Inrush current
Current consumption
Mirage 4K35 User Manual
020-101377-03 Rev. 1 (07-2015)
Low line: 200 - 230 VAC
High line: 380 - 415 VAC
Low line: 180 - 253 VAC
High line: 342 - 456 VAC
3
50 - 60 Hz nominal
120 A maximum
Low line: 35 A maximum
High line: 26 A maximum
8.8 kW max. (at max. output for 6kW lamp plus head)
37A
18 - 46 VDC
125 - 155 VDC
50 - 180 A
1% max (at 25°C, rated input and rated output)
Field wireable lugs
200 - 230 VAC
6 A
1 A
Both run from 15 A breaker (internal)
200 - 240 VAC
50 - 60 Hz nominal
70 A maximum
6 A maximum (at 200 VAC)
Specification