g. Connect the negative (-) black lamp lead to the negative (-) igniter terminal, left
terminal. Connect the positive (+) red lamp lead to the positive (+) igniter terminal, right
terminal.
Caution! Failure to comply with the following could result in minor or moderate injury.
When connecting the high current lamp leads between the LPS and the igniter, make sure
the black (-) power cable (cathode lead) is securely connected with the washers and lock
washers properly in place and tighten to 175 inch-lbs, 14 ft-lbs or 20Nm at both ends.
h. Tighten the strain reliefs.
i. Replace the igniter door.
j. Replace the rear lens-side cover.
5. Ensuring AC power is off at the supply, connect the AC directly to the LPS AC input terminal
block according to your region.
Caution! Failure to comply with the following could result in minor or moderate injury.
Use an appropriately sized strain relief connector with the knockout plate provided to ensure
adequate environmental sealing and to prevent the cable from accidentally being torn out.
For North America, Japan, Korea and most of Central/South America (200-230 VAC):
Wire Phase 1, 2, 3 and Ground
For Europe and China (380-415 VAC):
Wire Phase 1, 2, 3, Neutral and Ground
a. Loosen the six screws to remove the LPS side panel.
b. Move the AC input line voltage switch in the upper-left corner of the LPS to the left. When
using a 200 VAC supply, see
29, or to the right when using a 400 VAC supply see
VAC operation
c. Reinstall and secure the LPS side panel with six screws.
Notice. Failure to comply with the following may result in property damage.
Internal input line voltage switch setting must match AC available on site.
6. Connect one end of the line cord into the LPS power connector labeled Projector ONLY.
If using the longer DC cable kits, the projector head must be powered separately using Christie
recommended line cord provided for your region.
7. Connect the other end of the projector line cord into the plug on the bottom lamp-side of the
projector front bezel.
Warning! Failure to comply with the following could result in death or serious injury.
Do not access projector power directly from the building electrical source. When using the
power connectors to power the projector and/or an extraction unit, the power connector
terminal block must be terminated correctly to allow 200 - 240 VAC output. These
connectors are controlled with the power connector breaker. For details, see the
Interconnect Drawing provided with the projector.
Mirage 4K35 User Manual
020-101377-03 Rev. 1 (07-2015)
Configuring ballast settings for 200 VAC operation
on page 30.