Ii Maintenance; Periodical Check; Maintenance Procedure (Periodical Check Parts) - Konica Minolta bizhub C350 Service Manual

Hide thumbs Also See for bizhub C350:
Table of Contents

Advertisement

AD-501 Field Service Ver2.0 Sep. 2004

II Maintenance

1.

Periodical check

1.1

Maintenance procedure (Periodical check parts)

NOTE
• The alcohol described in the cleaning procedure of Maintenance represents the
isopropyl alcohol.
1.1.1
Transport Roller / Roll 1
1.1.2
Transport Roller / Roll 2, 3
[2]
[1]
4535fs2501c0
[1]
[3]
4535fs2502c0
A. Cleaning procedure
1. Remove the Duplex Unit.
☞ 2-4
2. Using a soft cloth dampened with
alcohol, wipe the Transport Roller /
Roll 1 [1] clean of dirt.
A. Cleaning procedure
1. Open the Duplex Unit Door [1].
2. Using a soft cloth dampened with
alcohol, wipe the Transport Roller /
Roll 2 [2], 3 [3] clean of dirt.
Periodical check
2-1