PC-401 Field Service Ver2.0 Sep. 2004

II Maintenance

1.

Periodical check

1.1

Maintenance procedure (Periodical check parts)

NOTE
• The alcohol described in the cleaning procedure of Maintenance represents the
isopropyl alcohol.
1.1.1

Separation Roller Assy

[1]
[3]
[4]
[5]
[8]
[2]
A. Cleaning procedure
1. Remove the Right Door.
☞ 2-7
2. Remove two screws [1] and remove
[1]
4348fs2509c0
3. Using a soft cloth dampened with
4348fs2510c0
B. Replacing procedure
[6]
1. Remove the Paper Separation Roller
☞ 2-1
2. Remove two C-rings [4] and the
[4]
NOTE
4348fs2511c0
• Be careful not to lose spring at this
time.
3. Remove the C-ring [7], the Guide [8],
[9]
[7]
4348fs2512c0
Periodical check
the Paper Separation Roller Mount-
ing Bracket Assy [2].
alcohol, wipe the Separation Roller
[3] clean of dirt.
Mounting Bracket Assy.
shaft [5], and remove the Paper Sep-
aration Roller fixing Bracket Assy [6].
and remove the Separation Roller
Assy [9].