2.6.49

C0F3D: Black ATDC Sensor adjustment failure

Imaging Unit /Bk
Step
Correct the ATDC connection on the underside of
1
the Imaging Unit if faulty.
Clean or correct each contact of the Imaging Unit
2
if faulty.
3
Change Imaging Unit.
4
Change PWB-MC
5
Change PWB-MFP.
2.6.50

C1200: Standard Controller configuration failure

MFP Control Board (PWB-MFP)
Step
Check to see if the following setting has been
correctly made: "Tech. Rep. Mode" → "System
Input" → "Peripheral Setting."
1
If the setting is changed, be sure to turn OFF and
ON the Power Switch.
Check the connectors of the MFP Control Board
2
(PWB-MFP) for proper connection and correct as
necessary.
3
Change PWB-MFP.
Relevant Electrical Parts
Control Board (PWB-MC)
MFP Control Board (PWB-MFP)
Action