bizhub C350 Field Service Ver2.0 Sep. 2004
Code
C0F33 Abnormally high toner density
detected Magenta ATDC Sensor
C0F34 Abnormally low toner density
detected Yellow ATDC Sensor
C0F35 Abnormally high toner density
detected Yellow ATDC Sensor
C0F36 Abnormally low toner density
detected Black ATDC Sensor
C0F37 Abnormally high toner density
detected Black ATDC Sensor
C0F3A Cyan ATDC Sensor adjustment fail-
ure
C0F3B Magenta ATDC Sensor adjustment
failure
C0F3C Yellow ATDC Sensor adjustment
failure
C0F3D Black ATDC Sensor adjustment
failure
C1200 Standard controller configuration
failure
C1203 File Memory mounting error
C1204 Memory capacity discrepancy
C1220 Image Input Time Out
C1229 Image Output Time Out
C1240 JBIG0 Error
C1241 JBIG1 Error
C1242 JBIG2 Error
C1243 JBIG3 Error
C1250 Compressor 0 command buffer
stop failure
C1251 Compressor 1 command buffer
stop failure
C1252 Compressor 2 command buffer
stop failure
C1253 Compressor 3 command buffer
stop failure
C1261 Compression hardware timeout
Item
• T/C 15.5 % or more is detected ten consecutive times
in the Developing Unit as validated through the toner
replenishing amount determination control.
• T/C 0.21 % or less is detected ten consecutive times
in the Developing Unit as validated through the toner
replenishing amount determination control.
• T/C 15.5 % or more is detected ten consecutive times
in the Developing Unit as validated through the toner
replenishing amount determination control.
• T/C 3 % or less is detected ten consecutive times in
the Developing Unit as validated through the toner
replenishing amount determination control.
• T/C 12 % or more is detected ten consecutive times in
the Developing Unit as validated through the toner
replenishing amount determination control.
• ATDC Sensor automatic adjustment does not function
properly, failing to adjust to an appropriate value.
• The controller of the MFP Control Board (PWB-MFP)
is faulty.
• The File Memory mounted on the MFP Control Board
(PWB-MFP) is faulty.
• The capacity of the File Memory mounted on the MFP
Control Board (PWB-MFP) is short.
• Image data is not input from the Image Processing
Board (PWB-C) to the MFP Control Board (PWB-
MFP).
• No image data is output from the MFP Control Board
(PWB-MFP).
• Memory of the MFP Control Board (PWB-MFP) is
faulty.
• The MFP Control Board (PWB-MFP) is faulty.
• The hardware involved with the compression function
offered by the MFP Control Board (PWB-MFP) does
not respond.
Malfunction code