C0040: Suction Fan Motor's Failure To Turn; C0046: Fusing Cooling Fan Motor /1'S Failure To Turn - Konica Minolta bizhub C350 Service Manual

Hide thumbs Also See for bizhub C350:
Table of Contents

Advertisement

Malfunction code
2.6.9

C0040: Suction Fan Motor's failure to turn

Suction Fan Motor (M12)
Step
Check the connector of motor for proper connection
1
and correct as necessary.
Check the fan for possible overload and correct as
2
necessary.
M12 operation check
3
4
Change PWB-MC
2.6.10

C0046: Fusing Cooling Fan Motor /1's failure to turn

Fusing Cooling Fan Motor/1 (M9)
Step
Check the connector of motor for proper connec-
1
tion and correct as necessary.
Check the fan for possible overload and correct as
2
necessary.
3
M9 operation check
4
Change PU-1
4-30
bizhub C350 Field Service Ver2.0 Sep. 2004
Relevant Electrical Parts
Control Board (PWB-MC)
Action
Relevant Electrical Parts
DC Power Supply (PU1)
Action
WIRING DIAGRAM
Control Signal
PWB-MC PJ18MC-9 (LOCK)
PWB-MC PJ18MC-7 (REM)
WIRING DIAGRAM
Control Signal
PU1 PJ17PU1-5 (LOCK)
Location
(Electrical
Component)
6-P
Location
(Electrical
Component)
2-K