Utility Mode
B. Mail Check
Functions
• To set whether or not to use Mail Check and the time interval for the POP3
Use
• To select not to use Mail Check
• To change the time interval for Mail Check
Setting/Procedure • The default setting is 15 min.
C. Connection Timeout
Functions
• To set the timeout period for connection during reception
Use
• To change the timeout period for connection during reception
Setting/Procedure • The default setting is 60 sec.
3.19.3

Send

A. SMTP server
Functions
• To set the SMTP server address for transmission used for the Remote Diagnosis
Use
• To set the address of the SMTP Server
Setting/Procedure • IP Address Version 4 format
[0 to 255]. [0 to 255]. [0 to 255]. [0 to 255]
B. SMTP Port Number
Functions
• To set the SMTP port number for transmission used for the Remote Diagnosis
Use
• To set the Port Number of the SMTP Server
Setting/Procedure • The default setting is 25.
C. Timeout of SMTP Server
Functions
• To set the timeout period for transmission
Use
• To change the timeout period for connection during transmission
Setting/Procedure • The default setting is 60 sec.
3.19.4

Status

Functions
• To carry out a transmission/reception test using the Remote Diagnosis System
Use
• To carry out a transmission/reception test using the Remote Diagnosis System
Setting/Procedure • Press the Start key to start transmission.
• The progress and results of the test are displayed on the screen.
3-38
server used for the Remote Diagnosis System for the standard controller
15 min.
(1 to 120 min., No)
60 sec.
(30 to 300 sec.)
System for the standard controller
System for the standard controller
25
(1 to 65535)
60 sec.
(30 to 300 sec.)
for the standard controller
for the standard controller
bizhub C350 Field Service Ver2.0 Sep. 2004