Konica Minolta bizhub C350 Service Manual page 269

Hide thumbs Also See for bizhub C350:
Table of Contents

Advertisement

Malfunction code
Code
C1265 Extraction hardware timeout
C1279 PCI-SDRAM DMA operation failure • The hardware involved with image transfer in the
C1290 Compression/extraction timeout
detection
C12B1 Image processing ASIC failure 1
C12B2 Image processing ASIC failure 2
C12B3 Image processing ASIC failure 3
C12B4 Image processing ASIC failure 4
C12C0 Hard disk recognition error
C12C1 Hard Disk Error 1
C12C2 Hard Disk Error 2
C12C3 Hard Disk Error 3
C12C4 Hard Disk Error 4
C12C5 Hard Disk Error 5
C12C6 Hard Disk Error 6
C12C7 Hard Disk Error 7
C12C8 Hard Disk Error 8
C12C9 Hard Disk Error 9
C12CA Hard Disk Error A
C12CB Hard disk data transfer error
C12CC Hard disk unformat
C12CF Hard disk specifications error
C12D0 Controller hardware error
C13C8 New Transfer Cleaner Unit reset-
ting failure
C13CA New Fusing Unit resetting failure
C13D1 Cyan Imaging Unit EEPROM
access error
C13D2 Magenta Imaging Unit EEPROM
access error
C13D3 Yellow Imaging Unit EEPROM
access error
C13D4 Black Imaging Unit EEPROM
access error
4-24
Item
• The hardware involved with the extraction function
offered by the MFP Control Board (PWB-MFP) does
not respond.
memory of the MFP Control Board (PWB-MFP) does
not respond.
• The hardware involved with the BTC compression
function offered by the MFP Control Board (PWB-
MFP) does not respond.
• Image processing ASIC (CPS2300S) on the MFP
Control Board (PWB-MFP) does not respond.
• Image processing ASIC (PIC1200S) on the MFP Con-
trol Board (PWB-MFP) does not respond.
• Image processing ASIC (PIC3400LITE) on the MFP
Control Board (PWB-MFP) does not respond.
• Image processing ASIC (BTCIF) on the MFP Control
Board (PWB-MFP) does not respond.
• Unable to communicate between the hard disk and
MFP Control Board (PWB-MFP).
• Hard disk is faulty.
• Data transfer from the hard disk is faulty.
• Unformatted hard disk is connected.
• A hard disk that falls outside the specifications is con-
nected.
• A controller hardware error is detected in the network
I/F.
• A new installation is not detected when a new Transfer
Cleaner Unit (Image Transfer Belt Unit) is installed.
• A new installation is not detected when a new Fusing
Unit is installed.
• A condition of "EEPROM is not connected" or "There
is an access error" is detected in EEPROM of the
Imaging Unit.
bizhub C350 Field Service Ver2.0 Sep. 2004
Description

Advertisement

Table of Contents
loading