Mechanical adjustment
3.
Mechanical adjustment
3.1
Adjustment of the solenoids
3.1.1
Adjustment of the Upper / Lower Entrance Switching Solenoid (SL1-FN)
[3]
[1]
3.1.2
Adjustment of the 1st Tray Entrance Selecting Solenoid (SL2-FN)
[2]
3.2
Timing belt tension adjustment
3.2.1
Adjustment of the Upper Entrance Motor (M4-FN) Timing Belt
[2]
[1]
3.2.2
Adjustment of the Lower Entrance Motor (M2-FN) Timing Belt
[2]
[1]
3-4
[2]
4684fs2503c0
[1]
4684fs2504c0
[3]
[1]
4684fs2505c0
[1]
4684fs2506c0
FS-501 Field Service Ver2.0 Sep. 2004
1. Loosen the screw [1] that secures
the solenoid in position.
2. Move the solenoid [2] up and down
and lower the lever [3] downward. At
this time, find a position at which the
clearance at portion A becomes 0.5
mm or less. Then, tighten the screw
[1].
1. Loosen the screw [1] that secures
the solenoid in position.
2. Move the solenoid [2] to the right or
left and, when dimension B mea-
sures 3.6 mm, tighten the screw [1].
1. Loosen two screws [1].
2. Move the mounting bracket [2] and
tighten the screw [1] so that the cen-
ter of the screw [1] on the upper right
side is located at the marked position
[3] of the mounting bracket [2].
1. Loosen two screws [1].
2. Move the mounting bracket [2] and,
when the belt deflects 2 mm at C,
tighten two screws [1].