Connecting A Serial Cable For Smdr - Comdial DX-80 Installation And Maintenance Manual

Hide thumbs Also See for DX-80:
Table of Contents

Advertisement

Connecting a Serial Cable for SMDR

SMDR (Station Message Detail Recording) can be output from the DX-80 system for use with serial printers of
collection in call accounting devices. Connection of the SMDR device to the DX-80 is accomplished through the serial
data port on the CPM labeled "SMDR." Connection to serial printers
may require customization of the serial cable used to make the
connection.
Whenever a call accounting system (third-party device) is deployed,
connection is often no more complicated than using a straight-through,
9-pin, female to male, serial cable. (Use Radio Shack model 26-117B
for good results.)
Connection to the PC/call accounting system is made via an available
9-pin serial port connector that is designated as COM1 or COM2 in the
PC configuration.
Once the cable is linked between the collection device and the DX-80
CPM-SMDR port, the collection device must be programmed for
compatible link protocol (baud rate). (At default the SMDR port baud
rate is set at 9600 bps.)
1
2
DCD
RXD
Serial Cable Installation Procedure
1.
Remove the KSU cover (four screws at each corner) of KSU1.
2.
Connect grounded wrist strap to a suitable earth ground. (If a grounded wrist strap is not available, bleed
any static charge from your body before touching circuit modules by touching the gold-painted surface of the
inside of the KSU cabinet. If the KSU is properly grounded this will momentarily discharge static electricity
from your body. NOTE: A GROUNDED WRIST STRAP IS THE BEST METHOD OF ASSURING THAT
STATIC ELECTRICITY DOES NOT DAMAGE CIRCUIT MODULES.)
3.
Locate the CPM and "SMDR" serial port on the CPM.
4.
Connect the male end of the 9-pin serial cable into this SMDR port.
5.
Connect the other end (female) of the 9-pin serial cable to the PC/collection device serial port.
6.
Replace the KSU cover.
P7290 IMM
DX-80 I
NSTALLATION AND
SMDR 9-pin Serial Cable Pin Designations
3
4
5
TXD
DTR
GND
2-18
M
M
AINTENANCE
ANUAL
CPM
"SMDR" serial port connector
(straight-
(Dedicated means that this AC
outlet has no other equipment
connected on this circuit
breaker.
6
7
DSR
RTS
8
9
CTS
RI

Advertisement

Table of Contents
loading

Table of Contents