Section 6 • Schematics
Platform Control Box Wiring Diagram- Load Sensor Option,
All Models (after serial number 16303)
A
B
C
1
2
3
GROUND
BOLT
4
CABLE
CABLE
CABLE
TILT
#3
#2
#1
ALARM
5
TURNTABLE
PRIMARY BOOM
ROTATE
NC
NO
UP/DOWN
6
NC
BP1
NO
7
PLATFORM
PLATFORM
HORN
LEVEL
P3
NO
TS9
TS7
8
6 - 79
Genie Z-45/25 & Genie Z-45/25J
First Edition • Second Printing
D
E
PLATFORM CONTROL BOX
WHT-LOAD (P/N 54908)
JIB
WHT-(F.S.) (P/N 54904)
110
F.S.
CABLE TO LOAD CELL (P/N 56765)
CABLE
PRIMARY
SEC.BOOM
BOOM
BP2
EXTEND/
RETRACT
TS13
BRN (P/N 54907)
DRIVE
SPEED
ROTATE
JIB
AUXILIARY PUMP
TS1
TS8
TS6
TS14
HIGH/LOW (2WD/4WD)
PLATFORM CONTROL SWITCH PANEL
Part No. 52709
F
G
H
LOAD SENSOR MODULE (COVER REMOVED)
(P/N 56766)
FUSE, 500 mA
-
+
N.O.
1
2
3
N.C.
4
C.
5
6
7
8
9
RED
LED
OVER LOAD
RELAY
OVER LOAD ADJUST
GENERATOR
OPTION
DRIVE
DP1
TS47
L1
+
DRV.ENA LED
DRV.ENA
TS15
HIGH/LOW
RPM
GLOW PLUG
START
L4
+
BRN
TS2
TS4
OVER LOAD LED
(P/N 32335)
I
J
K
L
BILL OF MATERIALS
PART NUMBER
DESCRIPTION
54904
WIRE ASSY FOOTSWITCH, SERV LOOP
54905
WIRE ASSY LOADSENSE, ORANGE LED
54906
WIRE ASSY FTSWTCH/LDSENSOR, PWR
54907
WIRE ASSY, LDSENSE, LED, GROUND
54908
WIRE ASSY LDSENS/FS, WHITE JUMP
54909
WIRE ASSY LDSENSE, BROWN, GROUND
PREALARM ADJUST
32335
LED,RED 12V LARGE
(NOT USED)
48716
DECAL, LABEL, LOAD SENSOR
56765
LOAD CELL BENDING TYPE
56766
MODULE,LOAD SENSE,1/12V RELAY
WHT
B
GRN
V
RED
R
BLK
N
YELLOW LED
PREALARM
(NOT USED)
NC
NC
EMERGENCY STOP
P2
M
N

Hide quick links: