Reference
A-18
Test
FEED SOLENOID ON
Xerox Internal Use Only
Procedure
5. Click the Stop button to stop the test.
Test Example:
[14:14]
Digital Output Mode = ENTRY
[14:14]
MAIN MOTOR ON FULL = ON
STARTED = MAIN MOTOR ON FULL
[14:15]
Digital Output Mode = EXIT
The Feed Roller rotates when the MAIN
MOTOR ON FULL and the FEED SOLENOID
ON tests are executed at the same time.
1) Power on the printer, and start up the CE
Diag Tool.
2) Remove the Bypass Tray.
3) Select the MAIN MOTOR ON FULL and
FEED SOLENOID ON tests, and click the OK
button.
4) Check that the Feed Roller rotates.
Phaser 6000/6010 and WC 6015 MFP