ZyXEL Communications ZyWALL USG 200 Series User Manual page 978

Unified security gateway
Hide thumbs Also See for ZyWALL USG 200 Series:
Table of Contents

Advertisement

Appendix A Log Descriptions
Table 296 Device HA Logs (continued)
LOG MESSAGE
%s file not existed,
Skip syncing it for %s
Master firmware
version can not be
recognized. Stop
syncing from Master.
Device HA Sync has
failed when syncing %s
for %s due to bad
\"Sync Password\".
Device HA Sync has
failed when syncing %s
for %s due to bad
\"Sync From\" or
\"Sync Port\".
Device HA Sync has
failed when syncing %s
for %s.
Sync Failed: Cannot
connect to Master when
syncing %s for %s.
Backup firmware
version can not be
recognized. Stop
syncing from Master.
Sync failed: Remote
Firmware Version
Unknown
Master firmware
version should be the
same with Backup.
Update %s for %s has
failed.
Update %s for %s has
failed: %s.
Device HA has skipped
syncing %s since %s is
%s.
978
DESCRIPTION
There is no file to be synchronized from the Master when
syncing a object (AV/AS/IDP/Certificate/System
Configuration), But in fact, there should be something in the
Master for the device to synchronize with, 1st %s: The
syncing object, 2ed %s: The feature name for the syncing
object.
Synchronizing stopped because the firmware version file was
not found in the Master. A Backup device only synchronizes
from the Master if the firmware versions are the same
between the Master and the Backup.
The synchronization password was incorrect when attempting
to synchronize a certain object (AV/AS/IDP/Certificate/
System Configuration).
1st %s: The object to be synchronized, 2ed %s: The feature
name for the object to be synchronized.
The Sync From IP address or Sync Port may be incorrect
when synchronizing a certain object (AV/AS/IDP/Certificate/
System Configuration).
Synchronization failed when synchronizing a certain object
(AV/AS/IDP/Certificate/System Configuration) due to an
unknown reason, 1st %s: The object to be synchronized, 2ed
%s: The feature name for the object to be synchronized.
Synchronization failed because the Backup could not connect
to the Master. The object to be synchronized, 2ed %s: The
feature name for the object to be synchronized.
The firmware version on the Backup cannot be resolved to
check if it is the same as on the Master. A Backup device only
synchronizes from the Master if the Master and the Backup
have the same firmware versions.
The firmware version on the Master cannot be resolved to
check if it is the same as on the Master. A Backup device only
synchronizes from the Master if the Master and the Backup
have the same firmware versions.
The Backup and Master have different firmware versions. A
Backup device only synchronizes from the Master if the
Master and the Backup have the same firmware versions.
Updating a certain object failed when updating (AS/AV/IDP/
Certificate/System Configuration). 1st %s: The object to be
synchronized, 2ed %s: The feature name for the object to be
synchronized.
Updating a certain object failed when updating (AS/AV/IDP/
Certificate/System Configuration) due to some reason. 1st
%s: The object to be synchronized, 2ed %s: The feature
name for the object to be synchronized.
A certain service has no license or the license is expired, so it
was not synchronized from the Master. 1st %s: The object to
be synchronized, 2ed %s: The feature name for the object to
be synchronized, 3rd %s: unlicensed or license expired.