3013: Zesa-Evt-Configuration-Invalid - HP T9576G06 Management Manual

Snmp configuration and management manual
Table of Contents

Advertisement

Ethernet Subagent
Sample Message
98-07-08 11:49:38 \NOVA.$ZESA

3013: ZESA-EVT-CONFIGURATION-INVALID

Unconditional Tokens
ZEMS-TKN-SUBJECT-MARK
ZESA-TKN-SUBAGENT
ZEMS-TKN-EVENTNUMBER
ZEMS-TKN-CHANGE-REASON
ZEMS-TKN-STATE-PREVIOUS
ZEMS-TKN-STATE-CURRENT
ZEMS-TKN-SYMPTOM-STRING
ZEMS-TKN-USER-CONTENT
Conditional Tokens
None
Message Text
Object unavailable <1>-<2>, event number: <3>, cause: <4>,
previous state: <5>, current state <6>, symptom string: <7>
user content: <8>
ZESA-TKN-SUBAGENT
identifies the subject of the event (the Ethernet Subagent process). The DDL
heading of this token ("Ethernet-SNMP-subagent") is inserted in the message text
following "Object unavailable."
zesaProcessName
is the Ethernet Subagent process name specified for the subagent's private
zesaProcessName MIB object.
ZESA-EVT-CONFIGURATION-INVALID
is the event number (3013). The DDL AS clause of this value ("startup-
configuration-invalid") appears in the message text following "event number."
SNMP Configuration and Management Manual—424777-006
3013: ZESA-EVT-CONFIGURATION-INVALID
TANDEM.ETHSA.G06
Object unavailable Ethernet-SNMP-
subagent - \NOVA.$ZESA:384566222,
event number: internal-fault,
cause: internal-failed,
previous state: connected,
current state: disconnected,
symptom string:T0326G06_25JUN98_ETHSA:,
AWAITIOX error -1,
user content: undefined
Value
<1> ZESA-TKN-SUBAGENT
<2> zesaProcessName
<3> ZESA-EVT-CONFIGURATION-
INVALID
<4> ZEMS-VAL-INTERNAL-FAILED
<5> ZESA-VAL-STATE-ENABLED
<6> ZESA-VAL-STATE-DISCONNECTED
<7> configuration-fault-detail
<8> ZEMS-VAL-NULL
14-63
003012