Trap Multiplexer Subagent/Manager
trap-multiplexer-process
identifies the Trap Multiplexer process. You can specify from one through five
alphanumeric characters, but the first character must be alphabetic.
other-run-option
is any of the TACL RUN command options. Refer to the TACL Reference Manual
for more information about these options. HP recommends using at least the
NOWAIT option so that you can resume TACL operations once the subagent is
started.
?
displays help information.
startup-parameter
is one of the following parameters you can specify to control attributes of the Trap
Multiplexer process.
-a $agent-process
-b [backup-cpu-number]
-c $alternate-collector-process
-n process-priority
-p trap-port-number
-t ([tcpip-proc-name ]... )
-k [keep-alive-timer]
-o
-l log-file
-x
-a $agent-process
is the name of the SNMP agent process from which you want the Trap
Multiplexer to receive SNMP manager requests. If not specified, $ZSNMP on
the same system as the Trap Multiplexer you specify is assumed.
-b [backup-cpu-number]
specifies that the Trap Multiplexer is to run as a process pair and optionally
specifies a backup CPU number (0 through 15) identifying the CPU in which
you want the backup process to run. If the primary process fails, the backup
process automatically takes over. You can force the backup process to take
over and a new backup process to be created by setting the value of
ztmxSwitchToBackupNow in the ztmxProcess group from an SNMP manager
after the subagent is started.
-c $alternate-collector-process
identifies the EMS collector to which the Trap Multiplexer sends event
messages. The default is $0, the primary EMS collector, on the local node.
SNMP Configuration and Management Manual—424777-006