Port-Track Force-Shut - Cisco AJ732A - MDS 9134 Fabric Switch Command Reference Manual

Cisco mds 9000 family command reference guide - release 4.x (ol-18089-01, february 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

port-track force-shut

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
port-track force-shut
To force a shutdown of a tracked port, use the port-track force-shut command in interface
configuration submode. To reenable the port tracking, use the no form of the command.
Syntax Description
This command has no other arguments or keywords.
Defaults
None.
Command Modes
Interface configuration submode.
Command History
Release
2.0(x)
Usage Guidelines
Use the port-track force-shut to keep the linked port down, even though the tracked port comes back
up. You must explicitly bring the port up when required using the no port-track force-shut command.
Examples
The following example shows how to force the shutdown of an interface and the interfaces that it is
tracking.
switch# config terminal
switch(config)# interface fc 1/2
switch(config-if)# no port-track force-shut
Related Commands
Command
port-track enable
show interface fc
show interface
port-channel
Cisco MDS 9000 Family Command Reference
18-30
port-track force-shut
no port-track force-shut
Modification
This command was introduced.
Description
Enables port tracking.
Displays configuration and status information for a specified Fibre Channel
interface.
Displays configuration and status information for a specified PortChannel
interface.