Viewing T1/E1 Configuration and Alarm Information

Viewing Information For a T1 Port

To view T1 port parameters, enter the following command
where
is the slot number where the board is located, and
is the T1 port number
on the board on which you want to view information. For example, to view information for
Port 2 on the board in slot 5, enter
A screen similar to following displays for a
port:
T1
These parameters are described in the section,
Configuring a T1 Port on page 33-4. Please refer to that section for descriptions.
. The system time when the last change in Line Status (i.e., alarm) parame-
ter occurred.
. The type of loopback mode configured for this port through the
command or activated remotely through
. Loopback modes are described in Configuring a
FDL
T1 Port on page 33-4.
. A list of any alarms that have occurred on his port. The possible items in the list
are the same as those for
described in Viewing Information for all T1/E1 Ports in
the Switch on page 33-11.
. The total number of Loss of Signal (
) events that have been detected
LOS
on this port. An
event occurs after 175 contiguous pulse positions with no pulses (10
LOS
absent pulses on
ports). An
failure is cleared after the switch observes a single pulse.
E1
LOS
. The occurrence of either a bipolar violation or an excessive zeros
error. A bipolar violation is the occurrence of a pulse of the same polarity as the previous
pulse. In
coded signals, a bipolar violation is a pulse of the same polarity as the previ-
B8ZS
ous without being part of the zero substitution code. An excessive zeros error is the occur-
rence of more than 15 contiguous zeros in an
-coded signal; in a
-coded signal, it is
AMI
B8ZS
the occurrence of seven (7) or more contiguous zeros.