Release 5.2
Unable to start printer creation request
A request to start the creation of a Windows-based local printer has failed. This error indicates a corrupt system
or a software design error. (Action Code: B)
Unable to start printer deletion request
A request to start the deletion of a Windows-based local printer has failed. This error indicates a corrupt system
or a software design error. (Action Code: B)
Invalid file type found in preview file
When the supervisor's preview report was opened for viewing, an invalid file type was found. This may indicate
a corrupted file on disk. The next time this supervisor generates a preview report, the problem should disappear.
(Action Code: B)
Invalid packet type [xx] received
A packet was received that contained an invalid packet type, where "xx" is the hexadecimal packet type code in
error. If the error occurs very infrequently, then it could be due to transmission errors, otherwise it indicates that
the version of the client software is incompatible with the host software. (Action Code: Y, Z)
Database read request for unknown table: xx
The Windows Server process received a database read request for a table that it does not recognize. This proba-
bly indicates that the client software version is newer than the host software version. (Action Code: Z, B)
Database delete request for unknown table: xx
The Windows Server process received a database delete request for a table that it does not recognize. This proba-
bly indicates that the client software version is newer than the host software version. (Action Code: Z, B)
Database write request for unknown table: xx
The Windows Server process received a database write request for a table that it does not recognize. This proba-
bly indicates that the client software version is newer than the host software version. (Action Code: Z, B)
Unrecognized message (0xnnnn) received
A message was received that is unrecognized. "nnnn" gives the hexadecimal message type code. This probably
indicates that the client software version is newer than the host software version. (Action Code: Z, B)
Invalid file ID [0xnnnn] in WIN_XFER_RQST
A request to transfer a file to the PC has failed because the ID of the requested file is unknown. This probably
indicates that the client software version is newer than the host software version. (Action Code: Z, B)
Unable to send command to modem
Winserver was unable to send a command to the modem. (Action Code:D)
Unable to obtain SYSTEM database lock
The process was unable to obtain a system database lock which is needed to update the database.
Detail Position nnnn is unknown