Use the undo poe utilization-threshold command to restore the default power alarm threshold of
the PSE.
By default, the power alarm threshold for the PSE is 80%.
The system sends a Trap message when the percentage of power utilization exceeds the alarm
threshold. If the percentage of the power utilization always keeps above the alarm threshold, the
system does not send any Trap message. Instead, when the percentage of the power utilization drops
below the alarm threshold, the system sends a Trap message again.
Examples
# Set the power alarm threshold of PSE 7 to 90%.
<Sysname> system-view
[Sysname] poe utilization-threshold 90 pse 7

poe-power input-threshold

Syntax
poe-power input-threshold { lower | upper } value
undo poe-power input-threshold { lower | upper }
View
System view
Default Level
2: System level
Parameters
lower value: Specifies an under-voltage threshold in volts. The under-voltage threshold range, default
under-voltage threshold, and recommended under-voltage threshold vary with devices.
upper value: Specifies an over-voltage threshold in volts. The over-voltage threshold range, default
over-voltage threshold, and recommended over-voltage threshold vary with devices.
Description
Use the poe-power input-threshold command to configure an AC input under-voltage/over-voltage
threshold.
Use the undo poe-power input-threshold command to restore the default.
The default AC input under-voltage/over-voltage threshold varies with devices.
Examples
# Set the AC input under-voltage threshold to 181 V.
<Sysname> system-view
[Sysname] poe-power input-threshold lower 181
# Set the AC input over-voltage threshold to 264 V.
<Sysname> system-view
[Sysname] poe-power input-threshold upper 264