Section 4 Initial Setup

4.3 Initial Setup Example for the K3HB-C

4-6
The initial setup is explained in the following example.
Settings Example
The feed length is displayed to tenths of a millimeter (0000.0mm) using
a rotary encoder that outputs 250 pulses per rotation to measure a
feed length of 0.5 m.
• If the measurement value goes above 500.0, comparative output
OUT1 turns ON.
• If the measurement value goes below 700.0, comparative output
OUT2 turns ON.
Measurement
value
700.0
500.0
Comparative output OUT2
Comparative output OUT1
Setting the Prescale Value
The prescale value can be obtained using the following formula when
the output is to be displayed as 0000.0 mm.
Prescale value ( ) = 500/250 = 2
Prescale value of Input A, X (mantissa): ps. ax = 2. 0000=
Prescale value of Input B, Y (exponent): ps. ay = 10 00
Initial Setup Flow
●To change a set value, press the S [SHIFT] Key once to enable
changing the setting and then press the U [UP] Key to change the
value.
Press the M [MODE] Key to register the set value. The set value will
be registered and the next parameter will be displayed.
A Check the wiring and turn the power ON.
• The display will show "0".
B Set the function to F2 (phase differential inputs).
1. Move to the initial setting level by pressing the L [LEVEL] Key for at least
3 s (operation will stop).
2. Set "func" to "f2" and press the
C Set input type A to 00 (no-contact, normally open).
Set input type A "in-ta" to "00" and press the
Encoder
K3HB-C
0
10
M
[MODE] Key.
M
[MODE] Key.
250 pulses