Omron K3HB-C User Manual page 163

Digital indicators
Hide thumbs Also See for K3HB-C:
Table of Contents

Advertisement

Appendices
Level
Parameter name
Characters
lset. c
Linear
Linear current type
output
lset. v
Linear voltage type
lset. h
Linear output upper
limit
lset. l
Linear output lower
limit
u-no
Communi-
Communications unit
cations set-
number
tings
Baud rate
bps
len
Communications data
length
sbit
Communications stop
bits
Communications
prty
parity
sdwt
Send wait time
test
Test input
Output test
init
Set value initialization
pass
PASS output change
Hysteresis
hys
Advanced
function
off-d
Output OFF delay
settings
shot
Shot output
out-n
Output logic
Output refresh stop
o-stp
bnk-c
Bank selection
s-tmr
Startup compensation
timer
Standby sequence
stdby
Others
Linear output
---
calibration value H
Linear output
---
calibration value L
*1 Variable C0 is used for reading communications data.
*2 Set the "bank" parameter to "EV" when an event input (connector) is mounted as a standard feature or
has been added.
A-12
Setting range
Characters
0-20, 4-20
0-20 mA, 4-20 mA
0-5, 1-5, 0-10
0-5 V, 1-5 V, 0-10 V
Same as measurement
Same as measurement
value
value
Same as above
Same as above
0 to 99
0 to 99
9.6, 19.2, 38.4
9. 6, 19. 2. 38. 4
7, 8
7, 8
1, 2
1, 2
None, even, odd
none, even, odd
0 to 99
0 to 99
off, :9999 to 99999
OFF, 19999 to 99999
(0 to 99999)
(when time limit is OFF.
off, 0 to 99999
Lower limit of P is 0)
off, 0. 00. 00 to
OFF, 0 to 99999 (when
the time unit is min)
9. 59. 59
off, 00. 00. 0 to
OFF, 0.00.00 to 9.59.59
99. 59. 9
(when the time unit is hr:
min: s)
OFF 00.00.0 to 99.59.9
(when the time unit is
min: s: ms)
off, on
OFF, ON
ll, l, pass, h, hh, err
LL, L, PASS, H, HH, and
ERR
0 to 9999 (when time
0 to 9999
limit is OFF. Lower limit
0. 00. 00 to 0. 59. 59
00. 00. 0 to 09. 59. 9
of P is 0)
0.00.00 to 0.59.59
(when the time unit is hr:
min: s)
00.00.0 to 09.59.9
(when the time unit is
min: s: ms)
0 to 1999
0 to 1999
0 to 1999
0 to 1999
n-o, n-c
Close in alarm, open in
alarm
OFF, OUT, ALL
off, out, all
off, key, ev
OFF, KEY, EV
0. 0 to 99. 9
0.0 to 99.9
OFF, ON
off, on
---
---
---
---
Initial value
Decimal point
4-20 mA
---
1-5 V
---
99999
None
When the time unit is
hr: min: s; *.**.**
When the time unit is
min: s: ms; **.**.*
R: 19999
Same as above
P: 0
1
---
9.6
---
7
---
2
---
Even
---
20
---
OFF
None
When the time unit is
hr: min: s; *.**.**
When the time unit is
min: s: ms; **.**.*
OFF
---
PASS
---
1
None
When the time unit is
hr: min: s; *.**.**
When the time unit is
min: s: ms; **.**.*
0
---
0
---
Close in alarm
---
OFF
---
OFF*
---
0. 0
1
OFF
---
---
---
---
---
Unit
Set
value
---
---
EU
EU
---
kbps
bit
bit
---
ms
EU
---
---
EU
R: 100 ms
P: ms
R: 100 ms
P: ms
---
---
---
s
---
---
---