Omron K3HB-C User Manual page 78

Digital indicators
Hide thumbs Also See for K3HB-C:
Table of Contents

Advertisement

■ F2: Cycle
Input A
Hold
Measurement value
Referring to the following table, specify the prescale value
corresponding to the desired display unit.
Calculated value
Passing speed
L: Sensor interval (m)
Measuring Feed Cycles for Parts
Operation Configuration (Application)
• Basic Operation
The time T (s) from one input A ON to the next is displayed.
The measurement value can be obtained using the following
formula:
D = T
T: Time (s) between input A rising edges
: Prescale value A
D: Cycle
T
T
1
2
T
R
T
No measurement
1
5.2 Setting the Function for the K3HB-P
Display unit
mm/s
m/s
m/min
cm/s
cm/min
km/h
T
T
T
3
4
5
Measurements T3 and T4 are not valid.
T
2
Prescale value
( )
1000 L/60
L/60
L
100 L/60
100 L
0.06 L
T
5
5-17