5.24 Changing Normal Display Values to Maximum
and Minimum Values
2
disp
L
(DISP)
0
L
Displays "L 0."
sv. dsp
2
L
off
Displays "L 2."
disp
2
L
pv
disp
2
L
pv
disp
2
L
max
ret
2
L
10
123. 4
123. 4

5.24 Changing Normal Display Values to Maximum and Minimum Values

The PV display value displayed after power is turned ON, after a
RESET input, immediately after moving to the RUN level, and
immediately after automatic display return to the RUN or adjustment
levels can be set to any of the following: present value, maximum
value, or minimum value.
The display value selection is set using the following parameter.
Parameter
Display value selection
disp
Parameter Setting Procedure
A Press the L [LEVEL] Key for at least 3 s in RUN level to move to
L
the initial setting level.
3 s min.
0" is displayed on the level/bank display to indicate the initial
• "
L
setting level.
B Press the L [LEVEL] Key several times to move to the display
L
adjustment level.
2" is displayed on the level/bank display to indicate the display
• "
L
adjustment level.
C Press the M [MODE] Key to change the PV display to "disp."
M
D Press the S [SHIFT] Key to make the SV display flash.
S
• The setting can be changed when the SV display starts to
flash.
E Use the U [UP] Key to change the set value.
U
F Press the M [MODE] Key to switch to the next parameter.
M
• The set value is registered.
G Press the L [LEVEL] Key for at least 1 s to return to RUN level.
L
1 s min.
"5.25 Displaying/Not Displaying Comparative Set Values"
Remarks
"5.27 Using the Position Meter"
"5.28 Automatic Return to Normal Display"
Display adjustment level
Set value
Meaning of set value
pv
Present value
max
Max. value
min
Min. value
P.5-71
P.5-73
R
P C
P.5-68
5-67