5.22 Holding Measurement Values

1
memo
L
(MEMO)
0
L
0."
Displays "
L
compn
1
L
0
1."
Displays "
L
memo
1
L
off
This function holds measurement values in the event of a power
interruption. You can specify that measurement values be held or not
held.
This function can be used to control fluctuations in the measurement
value even if the device momentarily stops.
Measurement value
Power supply
* Holds values even in overflow or no-measurement status.
* Holds values even if a software reset is performed by key operations
or communications.
* The interruption memory cannot be accessed if the startup
compensation timer is enabled when the power is turned ON.
* When the interruption memory is enabled, maximum and minimum
values are also held when there is a power interruption. (This is also
possible for the K3HB-R/P.)
Use the following parameter to set the interruption memory parameter.
Parameter
Interruption memory
memo
Parameter Setting Procedure
A Press the L [LEVEL] Key for at least 3 s in RUN level to move to
L
the initial setting level.
3 s min.
0" is displayed on the level/bank display to indicate the initial
• "
L
setting level.
B Press the L [LEVEL] Key several times to move to the input
L
adjustment level.
1" is displayed on the level/bank display to indicate the input
• "
L
adjustment level.
C Press the M [MODE] Key to switch to the PV display to "memo".
M
5.22 Holding Measurement Values
Input adjustment level
Hold
Recover
OFF
ON
Set value
Meaning of set value
on
Interruption memory
enabled
off
Interruption memory
disabled
C
5-63