Digital indicators
Hide thumbs Also See for K3HB-C:
Table of Contents

Advertisement

0
L
Displays "L 0."
amov
0
L
0
amov
0
L
00000
init
f
L
off
Displays "L f."
shot
f
L
0
shot
f
L
0000
shot
f
L
0010
Important
out-n
f
L
n-o
0
L
123. 4
123. 4
Remarks
Parameter Setting Procedure
A Press the L [LEVEL] Key for at least 3 s in RUN level to move to
L
the initial setting level.
3 s min.
0" is displayed on the level/bank display to indicate the initial
• "
L
setting level.
B Press the M [MODE] Key several times to change the PV display
M
to "amov."
• This parameter is not displayed for the initial status due to setting
level protect.
Refer to "5.34 Limiting Key Operations" (P.5-84) for information
on removing setting level protect.
C Press the S [SHIFT] Key to make the SV display flash.
S
• The setting can be changed when the SV display starts to
flash.
D Use the U [UP] and S [SHIFT] Keys to set the password "-
U
0169." Press the M [MODE] Key to move to the advanced
function setting level.
M
f" is displayed on the level/bank display to indicate the
• "
L
advanced function setting level.
E Press the M [MODE] Key several times to change the PV display
M
to "shot."
F Press the S [SHIFT] Key to make the SV display flash.
S
• The setting can be changed when the SV display starts to
flash.
G Use the U [UP] and S [SHIFT] Keys to change the set value.
U
Set the shot output time (shot) to "0" to use the OFF delay (off-d).
If set to anything else, off-d (OFF delay) will be disabled.
H Press the M [MODE] Key to switch to the next parameter.
M
• The set value is registered.
I Press the L [LEVEL] Key for at least 1 s to return to the initial
L
setting level.
1 s min.
J Press the L [LEVEL] Key for at least 1 s to return to RUN level.
L
1 s min.
"5.13 Delaying Output OFF Timing"
5.12 Outputting for a Set Interval
P.5-46