Preventing Operation Of Cross-Point Buttons; Preventing Operation Of Cross-Point Buttons (Inhibit Function); Preventing Operation Of A Cross-Point Button Row (Protect Function) - Sony MKS-X1115 User Manual

Live production processor system
Table of Contents

Advertisement

Preventing Operation of
Cross-point Buttons
Preventing Operation of Cross-
Point Buttons (Inhibit Function)
For each cross-point button in the cross-point control
block, you can temporarily inhibit operations.
To enable/disable the inhibit function, use the following
buttons.
• ICP-X7000: [XPT INHBT SET] button and [XPT
INHBT ALLCLR] button assigned to the cross-point
pad
• ICP-X1000 series: [INHBT SET] button and [INHBT
ALLCLR] button assigned to the function button
section
When a cross-point button is set to inhibited, the
operation of all cross-point buttons with the same number
in the cross-point button rows are inhibited.
To inhibit a cross-point button
Press and hold the [XPT INHBT SET] button/[INHBT
SET] button, and press the target cross-point button to set.
While the [XPT INHBT SET] button/[INHBT SET]
button is pressed, the inhibited buttons flash amber.
Notes
• When a cross-point button is inhibited, the button turns
off and the display signal name is not displayed.
• Even when you inhibit a cross-point button, macro
attachment settings are still possible.
• You can inhibit cross-point buttons for each cross-point
assign table using the Home > Setup > Xpt Assign >
Table Button Assign menu (19102.31).
For details about setting inhibit mode, see "Creating
Tables 1 to 14" (page 388).
To release the inhibit setting for a cross-point
button
Press and hold the [XPT INHBT SET] button/[INHBT
SET] button, and press the target cross-point button to
release.
To release the inhibit setting for all cross-point
buttons
Press and hold the [XPT INHBT SET] button/[INHBT
SET] button, and press the [XPT INHBT ALLCLR]
button/[INHBT ALLCLR] button.
Preventing Operation of a Cross-
Point Button Row (Protect Function)
You can temporarily prevent button operations for each
cross-point button row on the cross-point control block.
To enable/disable the protect function, use the following
buttons.
• ICP-X7000: [ROW-1 PROT] button to [ROW-4
PROT] button assigned to the cross-point pad
• ICP-X1000 series: [PROT] button in the 1st row to 4th
row assigned to the function button section
To protect a cross-point button row
Press the [ROW-1 PROT] button to [ROW-4 PROT]
button/[PROT] button, turning it on, for the target cross-
point button row (1st row to 4th row) to set.
To release the protection setting for a cross-
point button row
Press the [ROW-1 PROT] button to [ROW-4 PROT]
button/[PROT] button, turning it off, for the target cross-
point button row (1st row to 4th row) to release.