Cross-Point Button Display - Sony MKS-X1115 User Manual

Live production processor system
Table of Contents

Advertisement

Notes
• The [SHIFT ALL] button is enabled, even if the
[SHIFT] button use is disabled.
The button numbers are as follows.
- 36-button row: 1 to 36 (unshifted state) to 37 to 72
(shifted state)
- 24-button row: 1 to 24 (unshifted state) to 25 to 48
(shifted state)
• The [SHIFT ALL] button is disabled in the following
cases.
- In [SHIFT] button hold mode
- When dual background bus mode is set
- When dual M/E is set
AUX bus control block
Each cross-point button and delegation button has two
button numbers, and you use the [SHIFT] button to
switch between these numbers.
When second delegation mode is enabled
In a 36-button row, the button numbers are as follows.
Button
Button number
when the [SHIFT]
button is off
1st (left side) to
1 to 35
35th buttons
The rightmost (36th) button is used as the [SHIFT]
button.
When selecting the bus/signal of button numbers 1 to 35,
press the corresponding number button.
When selecting the bus/signal of button numbers 36 to 70,
press the [SHIFT] button, turning it on, and press the
corresponding number button.
When second delegation mode is disabled
In a 36-button row, the button numbers are as follows.
Button
Button number
when the [SHIFT]
button is off
1st row and 3rd
1 to 35
row:
1st (left side) to
35th buttons
2nd row and 4th
row:
1st (left side) to
35th buttons
The rightmost (36th) button is used as the [SHIFT]
button.
When selecting the bus/signal of button numbers 1 to 35
in the 1st row and 3rd row, press the corresponding
number button.
When selecting the bus/signal of button numbers 36 to 70
in the 2nd row and 4th row, press the corresponding
number button.
When selecting the bus/signal of button numbers 36 to 70
in the 1st row and 3rd row, press and hold the [SHIFT]
button and press the corresponding number button.
[SHIFT] button
The [SHIFT] button has two operation modes.
Hold mode: Mode where the shifted state is selected
Lock mode: Mode where every time the button is pressed,
In cross-point button rows (3rd row/4th row), you can
also disable the shift button function.
For details about setting delegation button rows, see
"Setting the operation mode of the shift button"
(page 415).
For details about setting cross-point button rows, see
"Setting the [SHIFT] button operation mode"
(page 388).
Notes
• When second delegation is disabled, the 1st row and 3rd
Button number
when the [SHIFT]
button is on
36 to 70
• The rightmost button operates as a cross-point button

Cross-Point Button Display

Names of signals
You can attach a name (logical V/K pair name or source
Button number
when the [SHIFT]
name) to the signal assigned to a cross-point button, with
button is on
a maximum of 16 characters.
36 to 70
The specified signal name appears on the display of the
cross-point control block/AUX bus control block (AUX
bus operation mode). When a signal in the shifted state of
a cross-point button is selected, the name of the shifted-
36 to 70
state signal is displayed.
Six types of display mode can be set according to the
information to display. The display mode can be switched
using the following buttons.
• ICP-X7000: Select display mode 1 to 6 using the
• ICP-X1000 series: The display mode switches each
For details about setting the signal name display, see
"Setting Logical V/K Pair Names/Source Names and
93
while the button is pressed
it toggles between the shifted state and unshifted state
row shift buttons are set to hold mode (fixed). You can
select the button number in the shifted state while
pressing the shift button.
The 2nd row and 4th row are always in the shifted state,
hence the shift buttons cannot be operated.
when the [SHIFT] button use is disabled in the cross-
point button row.
In a 36-button row, it becomes button number 36.
display mode buttons assigned to the cross-point pad.
time the [DISP MODE] button assigned to the function
button section is pressed.

Advertisement

Table of Contents
loading

Table of Contents