Sony MKS-X1115 User Manual page 24

Live production processor system
Table of Contents

Advertisement

Function name
Button
name
Others:
P/P
M/E Status
M/E1 to
M/E5
Row-n Bus:
A
a) b)
Bkgd A
B
a) b)
Bkgd B
Row-n Bus:
KEY1 to
a) c)
Key 1 to Key 8
KEY8
d)
Row-n Bus:
UTL1
a) c)
Utility 1
UTL2
a) c)
Utility 2
Row-n Bus:
DME EXT
a) c)
DME External
Row-n Bus:
DME UTL1
a) c)
DME Utility 1
DME UTL2
a) c)
DME Utility 2
Row-n Bus:
FMS1
a) b)
FM Source 1
FMS2
a) b)
FM Source 2
Row-n Bus:
DME1V to
DME1 Video to
DME4V
a) b)
DME4 Video
Row-n Bus:
DME1K to
DME1 Key to
DME4K
a) b)
DME4 Key
Row-n Aux:
EDIT PVW
a) b)
Edit Preview
Row-n Aux:
AUX1 to
a) b)
Aux 1 to Aux 48
AUX48
Row-n Func:
UTL/SB1 to
Utility/Shotbox 1 to
UTL/SB10
a)
Utility/Shotbox 10
c)
Description
Displays the currently
set switcher bank.
In multi program 2
mode, the main and sub
assignment status
(MAIN, SUB, M&S) is
also displayed.
Assigns background A
and B buses to the 1st
row to 4th row.
n = 1 to 4
Assigns key 1 to 8
buses to the 1st row to
4th row.
n = 1 to 4
Assigns utility 1 and 2
buses to the 1st row to
4th row.
n = 1 to 4
Assigns DME external
video bus to the 1st row
to 4th row.
n = 1 to 4
Assigns DME utility 1
and 2 buses to the 1st
row to 4th row.
n = 1 to 4
Assigns frame memory
source 1 and 2 buses to
the 1st row to 4th row.
n = 1 to 4
Assigns DME1 to DME4
video buses to the 1st
row to 4th row.
n = 1 to 4
Assigns DME1 to DME4
key buses to the 1st row
to 4th row.
n = 1 to 4
Assigns edit preview
bus to the 1st row to 4th
row.
n = 1 to 4
Assigns AUX1 to 48
buses to the 1st row to
4th row.
n = 1 to 4
Assigns utility/shotbox
banks 1 to 10 to the 1st
row to 4th row.
n = 1 to 4
24
Function name
Button
name
Row-n Func:
XXX
Assign Status
Row-n Func:
XPT HOLD Sets cross-point hold for
d) e)
Xpt Hold
Others:
XPTHLD A
Xpt Hold BKGD A
XPTHLD B
Xpt Hold BKGD B
Others:
XPTHLD
Xpt Hold Key 1 to
KEY1 to
d)
Xpt Hold Key 8
XPTHLD
KEY8
Others:
XPTHLD
Xpt Hold Utility 1
UTL1
Xpt Hold Utility 2
XPTHLD
UTL2
Others:
XPTHLD
Xpt Hold DME
DME EXT
External
Others:
XPTHLD
Xpt Hold DME
DME UTL1
Utility 1
XPTHLD
Xpt Hold DME
DME UTL2
Utility 2
Others:
XPTHLD:
Xpt Hold Status
AB U12
K1234
K5678
Row-n Func:
XXX
Xpt Button No.285
to Xpt Button
e)
No.300
Row-n Func:
ROWn
Table 1 to Table 14
TBL: 1 to
h)
TBL: 14
Description
Displays the bus/
function name assigned
to the 1st row to 4th
row.
If a table is assigned
that is different from the
cross-point assign table
configured on the
switcher bank, the
selected table (TBL: 1
to TBL: 14) is also
displayed.
n = 1 to 4
XXX = Bus or function
name
the buses assigned to
the 1st row to 4th row.
n = 1 to 4
Sets cross-point hold for
the background A and B
buses.
Sets cross-point hold for
the key 1 to 8 buses.
Sets cross-point hold for
the utility 1 and 2 buses.
Sets cross-point hold for
the DME external video
bus.
Sets cross-point hold for
the DME utility 1 and 2
buses.
Displays the buses for
which cross-point hold
is set.
Selects the cross-point
button number 285 to
300 signals in the 1st
row to 4th row.
Re-entry signals (M/E-1
to M/E-5 Out1, P/P
Out1, M/E-1 to M/E-5
Out5, P/P Out5) are
assigned to button
numbers 285 to 290
and 293 to 298.
n = 1 to 4
XXX = Signal name
Assigns cross-point
assign tables 1 to 14 to
the 1st row to 4th row.
n = 1 to 4

Advertisement

Table of Contents
loading

Table of Contents