Installing the Lens Cable
After installing the Jens cable, keep the
detecting lever D of the No. 4/5 mirror
mount off the cam gear @) so that the
cam gear will not come into contact with
the detecting fever when it rotates.
2)
Figure 4-245
While keeping the condition created in
step 1), turn on the power; then, turn off
the power when the No. 1 mirror mount
and the lens have stopped to operate.
¢ The No. 1 mirror mount moves to the
home position and the lens will shift to
the DIRECT position.
COPYRIGHT © 1995 CANONINC,
3)
Engage the detecting lever of the No.
4/5 mirror mount with the cam gear, and
make sure that the tip @ of the detecting
lever and the marking line @ on the top
face of the cam gear match.
Figure 4-246
4) If the tip of the detecting lever and the
marking line on the top face of the gear
do not match, remove the fixing screw
® of the cam gear, and change the
tooth engagement of the cam gear @
until the tip and the marking line match.
6)
Figure 4-247
5) Engage the detecting lever of the No.
4/5 mirror mount with the cam gear.