Pointek Cls300; Location; Mounting - Siemens Pointek CLS200 Operating Instructions Manual

Hide thumbs Also See for Pointek CLS200:
Table of Contents

Advertisement

5.2

Pointek CLS300

Note
• Installation shall only be performed by qualified personnel and in accordance with local
governing regulations.
• This product is susceptible to electrostatic shock. Follow proper grounding procedures.
• The housing may only be opened for maintenance, local operation, or electrical
installation.
• Before installing the instrument, verify that the environment complies with any
restrictions specified on the product nameplate.
• To comply with CE EMC regulations, where applicable, the CLS300 should be installed in
accordance with the testing details on Approvals (Page 86).
5.2.1

Location

Recommended:
• Provide a sun shield to protect the transmitter from direct heat radiation.
Precautions:
• Avoid mounting Pointek CLS300 Standard in locations subject to strong vibrations in the
vicinity, whenever possible.
• Do not exceed the permissible ambient temperature limits (see Environmental (Page 85)
for details).
5.2.2

Mounting

5.2.2.1
Mounting
Pointek CLS300 typical configuration:
For high level alarm (level exceeds normal process level):
• normally mounted into the vessel top, or
• mounted through the tank wall at the detection level
For low level alarm (level drops below normal process level):
• mounted through the tank wall at the detection level
Pointek CLS200/CLS300 digital
Operating Instructions, 05/2021, A5E47904060-AA
Installation
5.2 Pointek CLS300
21