Rc Data Over Flow Fail - Xerox Phaser 7500 Service Manual

Hide thumbs Also See for Phaser 7500:
Table of Contents

Advertisement

Error Messages and Codes

RC Data Over Flow Fail

Applicable Chain-Link Code
Initial Actions
3-240
The correction setting value of calculation result has exceeded the settable range.
089-616: RC Data Over Flow Fail
Power cycle the printer.
If the problem persists, follow the procedure below.
Troubleshooting Reference
Applicable Parts
LPH Unit (Y, M, C, K), PL2.1.2
Note
When multiple failures with Chain No. 089 occur, take action according to the
priority order.
Troubleshooting Procedure
Step
Actions and Questions
1
Raise/lower the LPH (Y, M, C, K) 2 to
3 times to check the LPH lift up/
down mechanism.
Is the problem repaired?
Wiring and Plug/Jack Map References
Yes
Troubleshooting
complete.
Phaser 7500 Printer Service Manual
No
Replace the
LPH Unit
(REP 2.1,
page
8-18).

Advertisement

Table of Contents
loading

Table of Contents