Error Messages and Codes
3-70
Troubleshooting Procedure (Continued)
Step
Actions and Questions
4
Check the wiring harness.
Check the connection between the
Motor Drive PWB J504 and the
Fuser Drive Motor J243 for open
circuit, short circuit, and poor
contact.
Is it conducting properly?
5
Perform the BTR 1/2 Contact &
Retract test in Diagnostics.
Does the Fuser Drive Motor rotate?
6
Check the connection between the
Fuser Drive Motor J243-8 and the
Motor Drive PWB J504-1 for open
circuit, short circuit, and poor
contact.
Is it conducting properly?
Yes
No
Replace the
Repair the
following parts
sections that
in sequence:
have short
circuits and
Fuser Drive
■
Motor (REP
poor contacts.
3.3,
page
8-28)
Motor Drive
■
PWB (REP
18.13,
page
8-204)
MCU PWB
■
(REP 18.12,
page
8-202)
Go to step 6.
Check the 1st
BTR Contact/
Retract Gear for
blockage and
damage.
Replace the
Repair the
following parts
sections that
in sequence:
have short
circuits and
Motor Drive
■
PWB (REP
poor contacts.
18.13,
page
8-204)
MCU PWB
■
(REP 18.12,
page
8-202)
Phaser 7500 Printer Service Manual