Ibt Motor Fail - Xerox Phaser 7500 Service Manual

Hide thumbs Also See for Phaser 7500:
Table of Contents

Advertisement

IBT Motor Fail

Phaser 7500 Printer Service Manual
The IBT Drive Motor rotation failure was detected.
Applicable Chain-Link Code
042-324: IBT Motor Fail
Initial Actions
Power cycle the printer.
If the problem persists, follow the procedure below.
Troubleshooting Reference
Applicable Parts
IBT Drive Motor Assy, PL3.3.4
MCU PWB, PL18.3.6
Motor Drive PWB, PL18.3.7
Troubleshooting Procedure
Step
Actions and Questions
1
Turn Off the power and remove the
IBT Unit.
Cheat the L/H Cover Interlock
Switch and turn On the power.
Perform the IBT Belt Motor test in
Diagnostics.
Does the IBT Drive Motor rotate?
2
Turn Off the power and remove the
M/C Rear Cover.
Turn On the power.
Is the voltage between the Motor
Drive PWB J508-5 (+) and the GND
(-) +24VDC?
3
Is the voltage between the Motor
Drive PWB J507-8 (+) and the GND
(-) +5VDC?
Error Messages and Codes
Wiring and Plug/Jack Map References
Yes
Go to step 5.
Go to step 3.
Go to step 4.
No
Go to step 2.
Refer to
"+24
VDC Power" on
page
4-16.
Refer to
"+5 VDC
Power
Troubleshooting
" on page
4-15.
3-113