Installation Specifications; Water Supply; Electrical; Space - Cornelius QUANTUM SERIES Installation And Service Manual

Corneilus installation & service manual beverage dispenser quantum series
Table of Contents

Advertisement

Quantum Series Installation and Service Manual
W
S
ATER
UPPLY
The Quantum Juice Dispensing machine is designed to dispense juice at a high flow rate. It is very
important that the incoming water line is dedicated for the unit, or at least does not have other
machines connected which could cause a water surge; i.e., a dishwashing machine.
NOTE: For increased cooling capacity the unit should be connected to a remote
recirculating cooling unit. If the location is equipped with a dedicated beverage wa-
ter supply system the juice dispenser should be connected to it.
NOTE: The water supply should be consistent with proper water quality standard
(neutral ph of 7.0 to 8.0), and should not be connected to a water softener. The wa-
ter cooling coil is Copper, and may be affected by poor water conditions (i.e. severe
corrosion and pitting).
Water connections shall be sized, installed, and maintained according to Federal, State, and Local
Laws.
E
LECTRICAL
A minimum of 15 amps electrical service is needed for 120V power supply or 10 amps for 220V
supply.
S
PACE
The minimum clearance is: 4" (10.16cm) in back and 12" (30.48cm) on top and open to the front if
sides are blocked off. If the sides are open then only 2" (5.08cm) is required in the back. Space
between the bottom of the unit and the counter cannot be obstructed.
NOTE: Condenser air is drawn from the bottom and discharged out the back. Fail-
ure to maintain clearance space will reduce capacity of the unit and cause prema-
ture compressor failure.
C
W
ONNECTING
ATER
1. Secure 3/8" (0.95cm) flexible hose to the unit water inlet. Make sure that the seal washer is
used (hose and seal washer are included with the installation kit).
2. When securing flare nut use backup wrench on male side of the fitting (unit side) to prevent
twisting of the copper tube inside the unit and/or possible damage to the water strainer/sole-
noid. A water shut off outside the unit is recommended.
F
U
ILLING
NIT WITH
To properly prime the unit with water, without air pockets in the system, push the dispensing
switches simultaneously for a few seconds each. Repeat above until a steady flow of water is
observed.
NOTE: Water splashing may occur during the purge cycle.