Head Loading Aux Controller Setting - Agilent Technologies E5035A Operation Manual

Hard disk read/write test system
Table of Contents

Advertisement

Figure H-4
Ramp Plate Thickness

Head Loading Aux Controller Setting

Follow the procedure below to set the head loading Aux controller.
The head loading Aux controller can be used both the tilt loading mechanism and the ramp
loading mechanism. There is a switch on it which changes the tilt mode or the ramp mode.
Set it to "Ramp" side as shown in Figure H-5, then LED is illuminated.
Figure H-5
Set Switch to Ramp
Plug the air fitting of
sown in Figure H-6 using an air stopper assembly.
WARNING
The air stopper assembly and two plugs as shown in Figure H-6 are included in the
Aux controller. Usually, plug the air fitting of
Load
off from the air fitting, when high air pressure is applied to the Aux controller
Appendix H
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
TILT AIR Down Load
using the air stopper assembly. Because, there is a possibility that the plug blows
and
TILT AIR Up Load
on the Aux controller as
and
TILT AIR Down Load
Ramp Load
Ramp Load
TILT AIR Up
435

Advertisement

Table of Contents
loading

Table of Contents