Measurement

TAA Measurement (Parametric)

Overview
This section describes the TAA measurement. TAA measurement is used to measure TAA
positive, TAA negative and TAA asymmetry. TAA measurement is measured by the
parametric module (E5038A).
Measurement
1. To open the TAA menu, click on the [TAA] button from the Parametric frame of the
Procedure
Figure 3-23
TAA Menu
NOTE
Before you execute this measurement, you should set an appropriate input range or execute
the Auto Configuration to set the input range automatically.
2. Set the parameters, click on each button to enter a new value.
66
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Measure menu.
Channel Bit Rate
Write Current
Sense Current
Data Pattern
Average
Track #
Specifies the speed at which data bits are
written on the media per second [bps].
Specifies the current applied to the write head.
Specifies the current applied to the read head.
Specifies the data pattern to be written on the
test track. To set the data pattern, click on the
[Configuration] > [Setup] > [Pattern Config]
buttons to open the menu.
Specifies the number of revolutions to get the
average results.
Specifies the track number to be tested.