Changes In Revision A.03.81 From Revision A.03.70 - Agilent Technologies E5035A Operation Manual

Hard disk read/write test system
Table of Contents

Advertisement

Changes in Revision A.03.81 from Revision A.03.70

For VEE program, the following measurements have been added.
Stability Measurement (Absolute Time Setting), This test allows the user to set up the
write and read operation in each segment as a function of absolute time so that test
results can be closely correlated similar to popcorn noise test.
For VEE program, the following parameters have been added and/or modified:
The following spindle speed limitations must be taken into account, when the user
specifies the 'RPM' parameter in the [Setup] menu. When RPM is set below 2400, the
system will automatically set the spindle speed to 2400[rpm]. When RPM is set above
2400, then the user's specified spindle speed will be used. Refer to the
"hpe5022_measureStability" and "hpe5022_measureAbsStability" functions of the
programming manual for details.
Appendix A
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Changes in Revision A.03.81 from Revision A.03.70
Spindle Speed Limitations
RPM = spindle speed, when spindle speed ≥ 2400 [rpm]
RPM = 2400 rpm, when the spindle speed is set below 2400