Ricoh FT5034 Service Manual page 37

Table of Contents

Advertisement

3. Take off the protective sheet only at both ends of the mirror.
4. Check that the rear spring plate is set properly.
5. Insert the mirror into the front side plate cut out and set it on the rear spring plate
properly.
6. Locate the bottom of the front spring plate and rotate the top of the spring into
position.
NOTE:
1. Install the mirrors with the
reflecting surface facing
the lens as shown.
7. Check whether the mirrors vibrate as shown.
If so, reinstall the spring plates after bending them.
NOTE: To prevent vibration, replace the
spring plates whenever the mirrors
are replaced.
8. Remove the rest of the protective sheet.
5. 1st Mirror Replacement
1. Remove the top cover (12 screws).
2. Remove the sub reflector (2 screws).
3. Remove the upper seal at the front side.
4. Free the lamp harness from the bracket (1
screw).
5. Lift the 1st scanner through the position
where the front frame is cut out.
6. Remove the front spring plate.
7. Pull the mirror towards the front of the
machine while holding the rear spring plate
with your fingers.
8. Remove the rear spring plate.
9. Take off the protective sheet only at both
ends of the mirror.
2. Attach the spring plate to
Spring plate
Reflecting
surface
Spring plate
- 36 -
the nonreflecting surface.
Check vibration
Sub Reflector
Front Spring Plate
Upper
Seal
Rear Spring Plate
Lamp Harness