BATTERY / ELECTRICAL
ADDITIONAL ROUTINGS
EGT SENSOR ROUTING
PIPE EGT SENSOR
q
1. The EGT sensor
is connected into the pipe. Route the EGT sensor wire toward the load center.
w
2. Take up some slack in the EGT sensor wire harness and secure to the load center bracket with a routing clip
.
e
3. Connect the EGT sensor connector
to the main harness connector.
9850064 R03 - 2021 650 / 850 Matryx Trail Performance / Crossover Snowmobile Service Manual