Service Manual
Equipment
Frequency Counter
Frequency Standard
Signal Source
Measuring Receiver/Spectrum
Analyzer
Signal Source Analyzer
AC Measurement Standard
Precision Type-N, Female-to-Female
Adapter, 50 Ω
Precision Type-N, Female-to-Female
Adapter, 75 Ω
50 Ω Type-N Female-to-BNC Male
Adapter
75 Ω Type-N Female-to-BNC Male
Adapter
50 Ω Directional Bridge
75 Ω Directional Bridge
Attenuator, 6 dB, 50 Ω, N-Type
Attenuator, 6 dB, 50 Ω, 2.92mm
Precision 50 Ω Open/Short Termination
Precision 75 Ω Open Termination
Precision 75 Ω Short Termination
Precision 50 Ω Feedthrough
[3]
Termination
Precision 75 Ω Feedthrough
[4]
Termination
Impedance Matching Pad, 75 / 50 Ω
Power Meter
[5]
Power Meter
Power Sensor, Thermal, 50 Ω
3-2
Table 3-1. Recommended Equipment
Recommended
Model
Fluke PM 6690
with 2.7 GHz Input option
Fluke 910R
Fluke 9640A, 96040A or
96270A
Rohde & Schwarz
FSMR26 with option FS-K40
Rohde & Schwarz FSUP with
option FSUP-B60
[1]
or
Agilent E5052B
Fluke 5790A
Maury Microwave 8828A
Maury Microwave 8882A
Maury Microwave 8821B1
Agilent 1250-1534
Agilent 86205A
Agilent 86207A
Weinschel Model 1-6
[2]
Anritsu Model 41KB-6
Narda Microwave 231-416
Maury Microwave 8885B
Maury Microwave 8884B
Rohde & Schwarz RAZ
Rohde & Schwarz NRVD
Rohde & Schwarz NRP2
Rohde & Schwarz NRV-Z51
or
Rohde & Schwarz NRP-Z51
Minimum Use Requirement
Period resolution: 100 ns
Frequency resolution: 10 nHz at 10 kHz.
-11
1 x 10
frequency uncertainty
4 GHz; frequency resolution 10 Hz, short term
amplitude stability 0.1dB
75 Ω Leveling Head required for testing 75 Ω UUTs.
Frequency resolution: 0.1 Hz
Frequency Accuracy: ± ½ count of lsd
Relative RF Level: ±(0.015 dB ±0.005 dB / 10 dB step)
Frequency: 1 kHz to 4 GHz
Range: +10 to -130 dBm; 50 Ω; Linearity uncertainty,
0.02 dB;
Max. SWR: 1.10; DC coupled;
Phase noise measurement capability: -128 dBc/Hz at
10 kHz and 100 kHz offset at 640 MHz
Phase noise sensitivity, without cross-correlation, at
1 GHz: -108 dBc/Hz at 100 Hz, -144 dBc/Hz at 100
kHz, and -165 dBc/Hz at 10 MHz offset
Phase noise sensitivity, normal capture range, at
1 GHz: -128 dBc/Hz at 1 kHz, -144 dBc/Hz at 100
kHz, and -170 dBc/Hz at 10 MHz offset
Accuracy: ± 0.1%, 200 Hz - 100 kHz
VSWR: DC to 4 GHz, ≤ 1.03; Insertion loss characterized:
100 kHz to 4 GHz
VSWR: DC to 2 GHz, ≤ 1.03; Insertion loss characterized,
100 kHz to 2 GHz
VSWR: DC to 4 GHz, ≤ 1.08
VSWR: DC to 3 GHz, ≤ 1.03
Directivity: 40 dB, 5 MHz to 2 GHz
Directivity: 40 dB, 5 MHz to 1.3 GHz
Male/female. VSWR: DC to 4 GHz, ≤ 1.15
Male/female. VSWR: DC to 26.5 GHz, ≤ 1.3
Minimum Reflection Coefficient: 0.99
Minimum Reflection Coefficient: 0.98
DC – 2 GHz
50 Ω ± 0.2%
75 Ω ± 0.2%
75 Ω Type-N (f) – 50 Ω Type-N (m)
Frequency range: DC to 2.7 GHz
Insertion loss: 1.76 dB
VSWR: 0 to 2 GHz, ≤ 1.06; 2 to 2.7 GHz, ≤ 1.2
Flatness: < 0.025 dB, DC – 0.5 GHz
Compatible with power sensors
Compatible with power sensors
Type-N Connector
Frequency: 100 kHz to 4 GHz
Power: +20 to -20 dBm
Cal factor uncertainty: ±0.3%;
Max. SWR: 1.10; DC coupled