Table 17. B7xxyyy Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
1732
1733
173A
173B
4091
4400
4401
4402
4705
Description
The VPD on a processor card is not
correct and the processor card cannot be
used, resulting in reduced processing
power.
System firmware failure. The startup
will not continue.
A VPD collection overflow occurred.
A system firmware failure occurred
during VPD collection.
Informational system log entry only.
There is a platform dump to collect
System firmware failure. The system
firmware detected an internal problem.
A system firmware error occurred while
attempting to allocate the memory
necessary to create a platform dump.
System firmware failure. A problem
occurred when initializing, reading, or
using the system VPD. The Capacity on
Demand function is not available.
Action
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
264.
Look for and correct B1xxxxxx errors. If there
are no serviceable B1xxxxxx errors, or if
correcting the errors does not correct the
problem, contact IBM support to reset the
server firmware settings.
Attention: Resetting the server firmware
settings results in the loss of all of the partition
data that is stored on the service processor.
Before continuing with this operation,
manually record all settings that you intend to
preserve.
The service processor reboots after IBM
Support resets the server firmware settings.
If the problem persists, Replace the
system-board, as described in "Replacing the
FRU system-board and chassis assembly" on
page 264.
1. Look for and resolve other errors.
2. If there are no other errors:
a. Update the firmware to the current
level, as described in "Updating the
firmware" on page 267.
b. You might also have to update the
management module firmware to a
compatible level.
Look for and correct other B1xxxxxx errors.
No corrective action is required.
1. Collect the platform dump information.
2. Go to "Isolating firmware problems" on
page 216.
Go to "Isolating firmware problems" on page
216.
Go to "Isolating firmware problems" on page
216.
Restart the system.
Chapter 2. Diagnostics
53