Table 16. B2xxyyyy Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
Reference Code
Description
B2003081
During the startup of a partition, the
startup did not complete due to a
copy error.
B2003084
A problem occurred during the
startup of a partition.
The adapter type might not be
supported.
B2003088
Informational system log entry only.
B200308C
A problem occurred during the
startup of a partition.
The adapter type cannot be
determined.
B2003090
A problem occurred during the
startup of a partition.
B2003110
A problem occurred during the
startup of a partition.
B2003113
A problem occurred during the
startup of a partition.
B2003114
A problem occurred during the
startup of a partition.
B2003120
Informational system log entry only.
B2003123
Informational system log entry only.
B2003125
During the startup of a partition, the
blade server firmware could not
obtain a segment of main storage
within the blade server to use for
managing the creation of a partition.
B2003128
A problem occurred during the
startup of a partition. A return code
for an unexpected failure was
returned when attempting to query
the load source path.
B2003130
A problem occurred during the
startup of a partition.
B2003135
A problem occurred during the
startup of a partition.
B2003140
A problem occurred during the
startup of a partition. This is a
configuration problem in the
partition.
B2003141
Informational system log entry only.
B2003142
Informational system log entry only.
B2003143
Informational system log entry only.
44
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Action
Check for server firmware updates; then, install the
updates if available.
Verify that the adapter type is supported.
No corrective action is required.
Verify that a valid I/O Load Source is tagged.
Go to "Isolating firmware problems" on page 216.
Go to "Isolating firmware problems" on page 216.
Look for B7xx xxxx errors and resolve them.
Look for other errors and resolve them.
No corrective action is required.
No corrective action is required.
Check for server firmware updates; then, install the
updates if available.
Look for and resolve B700 69xx errors.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Reconfigure the partition to include the intended load
source path.
No corrective action is required.
No corrective action is required.
No corrective action is required.