IBM PS703 Service Manual page 60

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 16. B2xxyyyy Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
Reference Code
Description
B2008111
A problem occurred during the
startup of a partition.
B2008112
During the startup of a partition, a
failure occurred; the startup will not
continue.
B2008113
During the startup of a partition, an
error occurred while mapping
memory for the partition startup.
B2008114
During the startup of a partition,
there was a failure verifying the
VPD for the partition resources
during startup.
B2008115
During the startup of a partition,
there was a low level
partition-to-partition communication
failure.
B2008117
During the startup of a partition, the
partition did not start up due to a
system firmware error.
B2008121
During the startup of a partition, the
partition did not start up due to a
system firmware error.
B2008123
During the startup of a partition, the
partition did not start up due to a
system firmware error.
B2008125
During the startup of a partition, the
partition did not start up due to a
system firmware error.
B2008127
During the startup of a partition, the
partition did not start up due to a
system firmware error.
B2008129
During the startup of a partition, the
partition did not start up due to a
system firmware error.
B200813A
There was a problem establishing a
console.
B2008140
Informational system log entry only.
B2008141
Informational system log entry only.
B2008142
Informational system log entry only.
B2008143
Informational system log entry only.
B2008144
Informational system log entry only.
B2008145
Informational system log entry only.
B2008150
System firmware detected an error.
48
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Action
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Check for server firmware updates; then, install the
updates if available.
Go to "Isolating firmware problems" on page 216.
Go to "Isolating firmware problems" on page 216.
Go to "Isolating firmware problems" on page 216.
Go to "Isolating firmware problems" on page 216.
Go to "Isolating firmware problems" on page 216.
Go to "Isolating firmware problems" on page 216.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
Collect a platform dump and then go to "Isolating
firmware problems" on page 216.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps704