Table 17. B7xxyyy Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
6908
6909
6911
6912
6944
6950
6951
6952
6953
6954
6955
6956
6965
6970
6971
56
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Description
System bus error
System bus error
Platform LIC unable to find or retrieve
VPD LID file.
Platform LIC unable to find or retrieve
VPD LID file.
Informational system log entry only.
A platform dump has occurred.
An error occurred because a partition
needed more NVRAM than was
available.
Informational system log entry only.
PHYP NVRAM is unavailable after a
service processor reset and reload.
Informational system log entry only.
Informational system log entry only.
An NVRAM failure was detected.
Informational system log entry only.
PCI host bridge failure
PCI bus failure
Action
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
264.
1. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
2. Go to "Isolating firmware problems" on
page 216.
Check for server firmware updates; then,
install the updates if available.
Check for server firmware updates; then,
install the updates if available.
No corrective action is required.
1. Collect the platform dump information.
2. Go to "Isolating firmware problems" on
page 216.
Use the Integrated Virtualization Manager
(IVM) to delete one or more partitions.
No corrective action is required.
Go to "Isolating firmware problems" on page
216.
No corrective action is required.
No corrective action is required.
Go to "Isolating firmware problems" on page
216.
No corrective action is required.
1. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
2.
If the problem persists, use the "PCI
expansion card (PIOCARD) problem
isolation procedure" on page 186 to
determine the failing component.
1. Use the "PCI expansion card (PIOCARD)
problem isolation procedure" on page 186
to determine the failing component.
2. If the problem persists, replace the
system-board and chassis assembly, as
described in "Replacing the FRU
system-board and chassis assembly" on
page 264.