Table 18. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
Error code
BA210003
BA210004
BA210010
BA210011
BA210012
BA210013
Description
A data storage error was caught by
partition firmware
An open firmware stack-depth assert
failed.
The transfer of control to the SLIC
loader failed
The transfer of control to the IO
Reporter failed
There was an NVRAMRC forced-boot
problem; unable to load the previous
boot's operating system image
There was a partition firmware error
when in the SMS menus.
Action
1. If the location code reported with the error
points to an adapter, check for adapter
firmware updates.
2. Apply any available updates.
3. Check for server firmware updates.
4. Apply any available updates.
5. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Use the SMS menus to verify that the
partition firmware can still detect the
operating system image.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
Chapter 2. Diagnostics
89