IBM PS703 Service Manual page 160

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 27. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
252B-719
252B
252B-720
252B
252B-721
252B
252B-722
252B
252B-723
252B
254E-201
254E 221
254E-601
254
254E-602
254
254E-603
254
254E-604
254
254E-605
254
254E-606
254
254E-701
254E 221
254E-702
254E 221
2567-xxx
2567
148
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Description and Action
Device bus termination power lost or not detected.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Adapter detected device bus failure.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Temporary adapter detected device bus failure.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Device bus interface problem.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board
Adapter configuration error. Go to "Performing the checkout procedure" on page 177.
Error log analysis indicates adapter failure. Go to "Performing the checkout procedure"
on page 177.
Error log analysis indicates an error attention condition. Go to "Performing the
checkout procedure" on page 177.
Error log analysis indicates that the microcode could not be loaded on the adapter. Go
to "Performing the checkout procedure" on page 177.
Error log analysis indicates a permanent adapter failure. Go to "Performing the
checkout procedure" on page 177.
Error log analysis indicates permanent adapter failure is reported on the other port of
this adapter. Go to "Performing the checkout procedure" on page 177.
Error log analysis indicates adapter failure. Go to "Performing the checkout procedure"
on page 177.
Error log analysis indicates permanent adapter failure. Go to "Performing the checkout
procedure" on page 177.
Error log analysis indicates permanent adapter failure is reported on the other port of
this adapter. Go to "Performing the checkout procedure" on page 177.
USB integrated system-board and chassis assembly. Go to "Performing the checkout
procedure" on page 177.