Table 11. 6xxxyyyy SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
6xxxyyyy
Description
Error Codes
632BCFC1
A virtual optical device cannot
access the file containing the
list of volumes.
632BCFC2
A non-recoverable error was
detected while reading the list
of volumes.
632BCFC3
The data in the list of volumes
is not valid.
632BCFC4
A virtual optical device cannot
access the file containing the
specified optical volume.
632BCFC5
A non-recoverable error was
detected while reading a
virtual optical volume.
632BCFC6
The file specified does not
contain data that can be
processed as a virtual optical
volume.
632BCFC7
A virtual optical device
detected an error reported by
the Network File System
server that cannot be
recovered.
632BCFC8
A virtual optical device
encountered a non-recoverable
error.
632CC000
Informational system log entry
only.
632CC002
self configuring SCSI device
(SCSD) selection or reselection
timeout occurred.
632CC010
Undefined sense key returned
by device.
632CC020
Configuration error.
632CC100
SCSD bus error occurred.
632CC110
SCSD command timeout
occurred.
632CC210
Informational system log entry
only.
632CC300
Media or device error
occurred.
34
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Action
On this partition and on the Network File System server, verify
that the proper file is specified and that the proper authority is
granted.
Resolve any errors on the Network File System server.
On the Network File System server, verify that the proper file is
specified, that all files are entered correctly, that there are no blank
lines, and that the character set used is valid.
On the Network File System server, verify that the proper file is
specified in the list of volumes, and that the proper authority is
granted.
Resolve any errors on the Network File System server.
On the Network File System server, verify that all the files specified
in the list of optical volumes are correct.
Resolve any errors on the Network File System server.
Install any available operating system updates.
632Cyyyy codes are virtual optical SRCs
No corrective action is required.
Refer to the hosting partition for problem analysis.
Refer to the hosting partition for problem analysis.
Refer to the hosting partition for problem analysis.
Refer to the hosting partition for problem analysis.
Refer to the hosting partition for problem analysis.
No corrective action is required.
Refer to the hosting partition for problem analysis.

Advertisement