v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Isolation
Symptom
Procedure Code
FSPSP01
A part vital to
system function has
been deconfigured.
Review the system
error logs for errors
that call out CRUs
that are relevant to
each reason code.
FSPSP02
This procedure is for
boot failures that
terminate very early
in the boot process
or when the
management card or
the VPD data on the
management card is
not operational or is
not present.
Action
If replacing parts does not resolve the error, perform one of the following
procedures, based on the SRC code that is called out after the FSPSP01
call.
If the SRC is B1xxB10C or B1xxB10D
The system has detected a deconfigured memory controller that is
required for the system to function, or it has detected that there is not
enough memory or that the memory is plugged incorrectly.
1. Reseat all of the memory DIMMs in the system enclosure but do not
replace any memory DIMMs at this time. Reseat the memory DIMMs
as described in "Installing a memory module" on page 251.
2. If the problem persists, replace each memory DIMM, by following the
action for symbolic FRU MEMDIMM.
3. Install the blade server into the BladeCenter unit after each DIMM
replacement and restart the blade to verify if the problem is solved.
4. If the problem persists after replacing all DIMMs, replace the system
board and chassis assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page 264.
If the SRC is B1xxB107 or B1xxB108
The system has detected a problem with a clock card.
1. Replace the system board and chassis assembly, as described in
"Replacing the FRU system-board and chassis assembly" on page 264.
If the SRC is B1xxB106
The system has detected that the planars are deconfigured.
1. Replace the system board and chassis assembly, as described in
"Replacing the FRU system-board and chassis assembly" on page 264.
If the SRC is B1xxB110 or B1xxB111
The system has detected that all of the I/O bridges are deconfigured.
1. Replace the system board and chassis assembly, as described in
"Replacing the FRU system-board and chassis assembly" on page 264.
1. Replace the management card, as described in "Removing the tier 2
management card" on page 262 and "Installing the tier 2 management
card" on page 263.
2. After replacing the card and installing the blade server in the chassis
unit and before rebooting the blade server or performing other
operations, ensure that the initialization of the management card VPD
occurs by waiting for the management module to discover the blade
server. Otherwise, the system might fail to IPL.
3. If the problem persists, replace the system board and chassis assembly,
as described in "Replacing the FRU system-board and chassis
assembly" on page 264.